Skip to main content

Development of a quadruplex loop-mediated isothermal amplification assay for field detection of four Vibrio species associated with fish disease

Abstract

A quadruplex loop-mediated isothermal amplification (LAMP) method was developed to detect four Vibrio species, including Vibrio ichthyoenteri, Vibrio parahaemolyticus, Vibrio scophthalmi, and Vibrio vulnificus, simultaneously. Four sets of species-specific primers were designed with different restriction sites contained in the inner primers. The quadruplex LAMP method could distinguish four Vibrio species via the subsequent restriction enzyme analysis. The sensitivity of the quadruplex LAMP method were 102–103 times higher than the sensitivity of conventional PCR. V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri could be detected in the different tissues of the infected fish by the quadruplex LAMP method simply and conveniently through using SYBR Green I to facilitate visual inspection of the LAMP products. The method we developed in this study could be a simple and convenient diagnostic tool for field detection of Vibrio infection in fish.

Background

In aquaculture, vibriosis is known as a major bacterial disease in fish culture systems and can cause considerable loss in terms of production and processing (Toranzo et al. 2005). Many Vibrio species have been recognized as fish pathogens that can cause infection with various symptoms. For example, Vibrio scophthalmi infection results in hemorrhage on fish body surface and inner surface of the abdomen, severe enteritis, and ascites (Qiao et al. 2012); Vibrio ichthyoenteri infection cause opaque intestines and necrotizing fasciitis with high mortality rates (Ishimaru et al. 1996; Lee et al. 2012); Vibrio parahaemolyticus infection causes diseases not only in fish, shrimp, oysters, and mussels, etc. (Montilla et al. 1994; Quintoil et al. 2007), but also is important in public health and causes gastrointestinal disorders in humans who ingest contaminated fish and shellfish (Kubota et al. 2008; Iwamoto et al. 2010); and Vibrio vulnificus has been associated with vibriosis outbreaks in fish and shellfish (Haenen et al. 2014) and can also cause severe, progressive necrotizing infection in human (Strom and Paranjpye 2000).

Rapid identification of the vibriosis pathogens to the species level is useful for research and epidemiological studies because identification can help with determining the exact source of any outbreak and in developing strategies to reduce the severity of the disease. However, the traditional identification techniques, which consist of a series of isolations on selective agar medium followed by biochemical and serological testing, are time-consuming and ambiguous (Harwood et al. 2004; Akond, et al. 2008). An array of molecular techniques has been gaining popularity for the identification of different aquaculture-related bacterial pathogens and includes the following: PCR-based identification methods for targeting 16S–23S rRNA intergenic spacer regions among vibrio species, including V. parahaemolyticus, V. vulnificus, etc. (Maria et al. 2010), a multipex PCR method was developed by using the rpoB gene to make the identificationg of Vibrio harveyi, V. ichthyoenteri, and Photobacterium damselae (Myoung et al. 2014), colony hybridization by species-specific probes to identify V. scophthalmi in the intestinal microbiota of fish and an evaluation of host specificity (Cerdà-Cuéllar and Blanch 2002), multiprobe fluorescence in in situ hybridization for the rapid enumeration of viable V. parahaemolyticus (Sawabe et al. 2009), and a simple and rapid PCR-fingerprinting method for V. cholerae on the basis of genetic diversity of the superintegron (Chowdhury et al. 2010).

The loop-mediated isothermal amplification (LAMP) method, developed in 2000 by Notomi et al. (2000) as a novel nucleic acid detection, is a desirable diagnostic tool for on-site epidemiological investigations of bacterial infection. Relying on its convenient operation, the short time required for results, and the high specificity, the LAMP method has been used in aquaculture as an effective method for pathogen detection. LAMP has been used widely for Vibrio detection in fish disease and shows high specificity, sensitivity and rapidity under isothermal conditions when used to identify a single Vibrio. Single pathogen LAMPs have been developed for Vibrio parahaemolyticus (Yamazaki et al. 2008), Vibrio nigripulchritudo (Fall et al. 2008), and Vibrio alginolyticus (Cai et al. 2010). In addition, many multiplex loop-mediated isothermal amplification (mLAMP) methods emerged in response to the need to detect two or more pathogens in one reaction system, and these mLAMP assays combined the LAMP technique with restriction enzyme analysis, constructing an original cleavage site within the amplification products rather than within the designed primers (Iwamoto et al. 2003; Iseki et al. 2007) to make this method more convenient and efficient in practice. This method has been used to confirm whether the amplification products are rooted in the target genes. He and Xu (2011) have successfully reported an mLAMP that detected two virus-inserted restriction enzyme cleavage sites in two pairs of species-specific primers, and Yu et al. (2013) developed a triLAMP (triplex loop-mediated isothermal amplification, triLAMP) method for detecting three Vibrio species successfully by designing primer sets with one or two restriction enzyme sites contained in the inner primers of each set. In addition, the results can be detected with the naked eyes by the addition of SYBR Green I, which is an important advantage in the development of a simple and rapid diagnostic tool.

In the present study, we developed an assay based on the LAMP technique for simultaneous detection of four Vibrio species in fish, and investigated its sensitivity, specificity, and application potential in fish. Our results indicated that the quadruplex LAMP method we constructed could identify four Vibrio species rapidly and accurately. This method will greatly help to detect pathogenic bacteria in fish farms.

Results and discussion

Optimization of the LAMP reaction conditions

To determine the optimal reaction temperature and time, the uni-LAMP was conducted using DNA template of V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri. The results of the LAMP amplification products by gel electrophoresis indicated that V. scophthalmi was detected at 58, 59, 60, 61, 62, 63, 64, and 65 °C (Fig. 1a); V. vulnificus was detected at 58, 59, 60, 61, 62, 63, 64, and 65 °C (Fig. 1b); V. parahaemolyticus was detected at 60, 61, 62, 63, and 64 °C (Fig. 1c); and V. ichthyoenteri was detected at 58, 59, 60, 61, 62, 63, and 64 °C (Fig. 1d). The 62 °C temperature was chosen for the subsequent assays on the basis of the brightness of the electrophoretic bands.

Fig. 1
figure 1

The optimization of the LAMP reaction temperature. LAMP reaction temperature of V. scophthalmi (a), V. vulnificus (b), V. parahaemolyticus (c) and V. ichthyoenteri (d) was set at 58–65 °C with 1 °C intervals, respectively. Lanes 2, 4, 6, 8, 10, 12, 14, and 16 were the amplification products, lanes 1, 3, 5, 7, 9, 11, 13, and 15 were negative control (the application templates used was ddH2O). M Marker. All products were electrophoresed on a 2 % agarose gel

At 62 °C, the LAMP products with the V. scophthalmi template displayed clear bands when the reaction was performed for 30, 45, 60, 75 and 90 min (Fig. 2a), whereas the LAMP products with the V. vulnificus, V. parahaemolyticus and V. ichthyoenteri template displayed clear bands when the reaction was performed for 45, 60, 75 and 90 min (Fig. 2). The 75 min reaction time was chosen as the time in which the subsequent assays were conducted based on the brightness of the electrophoretic bands. Based on these results, the optimal quadruplex LAMP reaction conditions were 62 °C for 75 min.

Fig. 2
figure 2

The optimization of LAMP reaction time. LAMP reaction time for V. scophthalmi (a), V. vulnificus (b), V. parahaemolyticus (c) and V. ichthyoenteri (d) was set at 15–90 min with 15 min intervals corresponding to lanes 1, 2, 3, 4, 5, and 6. M Marker. All products were electrophoresed on a 2 % agarose gel

Specificities of the quadruplex LAMP method

To examine the specificity of the quadruplex LAMP method, the assays were carried out with DNA templates of bacterial strains that included 26 Vibrio strains and 5 non-Vibrio strains (Table 1). The results showed positive results for all tested target Vibrio species (Table 1), whereas the other strains showed negative results (Table 1).

Table 1 Bacterial strains used in this study

With respect to the specificity level achieved in this study, the specific species could be discriminated by restriction enzyme analysis because different types of restriction enzyme cutting sites were introduced to the primers targeting these four Vibrio species. In addition, the assays indicated that only the tested strains belonging to V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri showed positive results, whereas other strains representing two other Vibrio species and five non-Vibrio species showed negative results.

Differential identification of the Vibrio species in the quadruplex LAMP

To identify the specific bacterial species which causes positive quadruplex LAMP result, the LAMP products were subjected to restriction enzyme digest. The results showed that the quadruplex LAMP products of V. scophthalmi could be only digested by EcoRI, while those of V. vulnificus, V. parahaemolyticus and V. ichthyoenteri could only be digested by BamHI, Pst I and EcoRV, respectively. The digests yielded a few small-size bands, which were distinguishable from those of LAMP products (Fig. 3). Hence, following the quadruplex LAMP reaction, the bacterial species can be easily identified by simple treatments of the amplicons with four different restriction enzyme digest systems.

Fig. 3
figure 3

Construction of the quadruplex LAMP reaction. The quadruplex LAMP products (a V. scophthalmi, b V. vulnificus, c V. parahaemolyticus, d V. ichthyoenteri) and their restriction enzyme-digestion maps. Lane 1 EcoRV digested products, Lane 2 Pst I digested products, Lane 3 BamH I digested products, Lane 4 EcoR I digested products, Lane 5 amplification products. All the quadruplex LAMP-amplified products and digested products were subjected to electrophoresis on a 2 % agarose gel

Sensitivity of the quadruplex LAMP method

Compared to conventional PCR methods, the detection limits of the quadruplex LAMP method rely on the initial inocula of V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri (8 × 108 CFU ml−1). A tenfold serial dilution of the culture was used, and the corresponding DNA was used for the subsequent quadruplex LAMP reaction and PCR. The LAMP reaction was able to detect V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri up to 8 × 103 CFU ml−1 (8 CFU per reaction) (Fig. 4), whereas the conventional PCR could detect V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri up to 8 × 105 CFU ml−1 (8 × 102 CFU per reaction) (Fig. 4a), 8 × 105 CFU ml−1 (8 × 102 CFU per reaction) (Fig. 4b), 8 × 106 CFU ml−1 (8 × 103 CFU per reaction) (Fig. 4c) and 8 × 105 CFU ml−1 (8 × 102 CFU per reaction) (Fig. 4d), respectively. The sensitivities of the quadruplex LAMP method were 103 times higher than observed for the PCR detection of V. parahaemolyticus and 102 times higher than conventional PCR in detecting V. scophthalmi, V. vulnificus and V. ichthyoenteri.

Fig. 4
figure 4

Sensitivities of the quadruplex LAMP and conventional PCR methods. Lanes 1–9 the quadruplex LAMP (eh) and general PCR (ad) were carried out using DNA extracted from different concentrations of V. scophthalmi (a, e), V. vulnificus (b, f), V. parahaemolyticus (c, g) and V. ichthyoenteri (d, h) as template. The bacteria concentration from lanes 1–8 were 8 × 106, 8 × 105, 8 × 104, 8 × 103, 8 × 102, 8 × 101, 8 × 100, and 8 × 10−1 CFU per reaction, respectively. M Marker. All products were electrophoresed on a 2 % agarose gel

Some differences exist between our method and methods previously reported for LAMP-based detection. In this study, we followed the protocol modified by Yu et al., who utilized crude tissue homogenates instead of the extracted DNA as templates and avoided having to use laboratory instruments (such as a centrifuge) that required for the DNA extraction process. The sensitivity of the quadruplex LAMP assay that positively detected among the V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri was 102–103 times higher than the sensitivity of the conventional PCR and was similar to the monoplex LAMP method and triplex reported previously (Mao et al. 2012; Yu et al. 2013).

Applicability of the quadruplex LAMP method for detecting Vibrio-infected fish under field conditions

To determine the practical applications of the quadruplex method for detecting Vibrio in fish, we utilized the boiled homogenates of various tissues such as blood, kidney, spleen and liver isolated from turbot, Scophthalmus maximus experimentally infected with V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri. The assays were conducted with only heating equipment and a water bath pot. Both are available on fish farms. The results indicated that four Vibrio species could be detected in all tissue samples by visual judgments of the quadruplex LAMP products stained with the SYBR Green I (Fig. 5), which is an important advantage in the development of a simple and rapid diagnostic tool.

Fig. 5
figure 5

Visual inspection of the quadruplex LAMP results. The boiled homogenates of the tissues collected from the fish that had been experimentally injected with PBS or vibrios (a V. scophthalmi, b V. vulnificus, c V. parahaemolyticus, and d V. ichthyoenteri) were used as templates. In all panels, Lane 1, 3, 5, and 7 represents spleen, kidney, liver and blood from the PBS-injected fish, respectively; Lane 2, 4, 6, and 8 represents spleen, kidney, liver, and blood from the infected fish, respectively

To evaluate the sensitivity of the quadruplex LAMP method in the blood, kidney, spleen and liver of infected fish by electrophoresis, the detection limits were 16 CFU per reaction, 11 CFU per reaction, 25 CFU per reaction, and 18 CFU per reaction, respectively, for V. scophthalmi; 19 CFU per reaction, 24 CFU per reaction, 15 CFU per reaction, and 10 CFU per reaction, respectively, for V. vulnificus; 23 CFU per reaction, 17 CFU per reaction, 19 CFU per reaction, and 13 CFU per reaction, respectively, for V. parahaemolyticus; and 15 CFU per reaction, 20 CFU per reaction, 10 CFU per reaction, and 22 CFU per reaction, respectively, for V. ichthyoenteri (Fig. 6). These results demonstrate that the quadruplex LAMP method was a feasible pathogenic diagnostic procedure for sensitive on-site detection of V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri.

Fig. 6
figure 6

The detection limits of the quadruplex LAMP method under site conditions. Blood, kidney, liver and spleen were collected from S. maximus infected with V. scophthalmi (a), V. vulnificus (b), V. parahaemolyticus (c), and V. ichthyoenteri (d), respectively. Tissue homogenates and blood were used as templates in the quadruplex LAMP method, which was conducted under field conditions. The detection limits, which are represented by bacterial numbers (of each reaction), are indicated on the Y-axis. Data are shown as the mean ± SD (N = 3)

To compare the sensitivity between electrophoresis and visual inspection (SYBR Green I), SYBR Green I was added into the tube at the end of the quadruplex LAMP, the results showed the detection limits were similar with that of electrophoresis (data not shown).

The limits of the quadruplex LAMP method for detecting Vibrio in fish tested using boiled homogenates of blood, kidney, liver and spleen from S. maximus infected with V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri ranged from 10 CFU per reaction to 25 CFU per reaction in the practical applicability. These limits prove that this method could satisfy the need for early diagnosis of Vibrio infection in fish and has the potential to be applied in aquaculture to avoid the tedious DNA extraction process. Furthermore, Yu et al. (2013) reported that the sensitivity of an on-site triLAMP method that utilized crude tissue homogenates instead of extracted DNA was similar to the triLAMP method with DNA template. Our findings showed that the detection limit results described from the use of crude tissue homogenates are similar to the quadruplex LAMP method with DNA template. These results were equal to the triplex loop-mediated isothermal amplification method reported previously (Yu et al. 2013).

Conclusions

In this study, we developed a quadruplex LAMP assay to achieve rapid, efficient and convenient detection of four Vibrio species, including V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri. This method is suitable for use under field conditions, and is helpful for fisherman to take emergency measures in order to prevent the spread of infection.

Methods

Bacterial species

The bacterial strains used in this study were listed in Table 1. Except for Staphylococcus aureus, which was cultured in Brain Heart Infusion (BHI) broth, all other strains were cultured in Luria–Bertani (LB) medium. All strains were cultured at 37 °C (for Escherichia coli, Micrococcus luteus and Staphylococcus aureus) or 28 °C (for all others).

DNA extraction

Bacteria cultured overnight(about 12 h) were washed three times with cold phosphate-buffered saline (PBS) by centrifuging at 11,000×g for 5 min and then resuspended in PBS and stored at 4 °C. The tenfold serial dilution plate counting method was used to determined the number of bacteria in a given population: at first, obtain 8 small, sterile test tubes, label the tubes 1 through 8 and then add 4.5 ml of PBS to each test tube, pipette 0.5 ml of the original bacterial cultured into test tube 1, and mixed thoroughly (using the vortexers on each bench) before proceeding to the next step, then obtained a clean pipette and withdraw 0.5 ml of the diluted bacterial suspension from the first test tube and pipette that into the second test tube. Continued in this fashion until we serially diluted the original bacterial suspension into test tube 8, the dilutions from test tube 1 to test tube 8 were from 1/10–1/108, the next step, just pipetted 0.5 ml of the diluted suspension from the appropriately diluted test tube onto the surface of the LB plate, after 18 h, calculated the number of colony forming units (CFU) on your plates. To calculate the number of bacteria per ml of diluted sample one should use the following equation:

$${\text{Number}}\;{\text{of}}\;{\text{CFU}}/\left( {{\text{Volume}}\;{\text{plated}}\;\left( {\text{mL}} \right) \times {\text{total dilution used}}} \right) = {\text{Number of CFU}}/{\text{mL}}$$

The concentration of the bacteria was determined by the serial dilution plate counting method mentioned above and adjusted to 8 × 109 CFU ml−1. The suspensions were boiled for 10 min and then centrifuged at 11,000×g for 5 min at 4 °C. The supernatants were transferred into new tubes and used immediately for LAMP reaction.

LAMP primers design

Based on the sequences of the luxR gene of V. scophthalmi (GenBank accession no. JN684209.1), the metalloprotease gene of V. vulnificus (GenBank accession no. U50548.1), the ompA gene of V. parahaemolyticus (GenBank accession no. JTGT01000603.1), and the ToxR gene of V. ichthyoenteri (GenBank accession no. KT265743), four sets of LAMP primers were designed with Primer Explorer 4.0 online software according to the principles proposed by Notomi et al. (2000) (Table 2). Each set contained four primers matching a total of six distinct fragments (from inner to outer: F1/F1c, F2/F2c, F3/F3c and B1/B1c, B2/B2c, B3/B3c) of the target gene, i.e., FIP against F1 and F2c, F3 primer against F3, BIP against B1 and B2c and B3 primer against B3. The inner primers were modified by inserting different restriction enzyme cleavage sites to the linking regions, in order to distinguish among different Vibrio species. For the primers designed for detecting V. scophthalmi, V. ichthyoenteri, V. vulnificus and V. parahaemolyticus, a EcoRI, EcoRV, Bam HI or Pst I site was introduced to FIP between F1c and F2, or BIP between B1c and B2 as shown in Table 2.

Table 2 The primers used in this study

LAMP reaction

The quadruplex LAMP was carried out in a 25 μl reaction volume containing 0.5 μl (1.6 μM) each of the two inner primers (FIP and BIP), 0.5 μl (0.4 μM) each of the two outer primers (F3, B3), 2.5 μl dNTPs (2.5 mM), 0.8 M betaine, and 1 μl (8 U) BstDNA polymerase with its corresponding 10× ThermoPol Buffer, and 1 μl DNA template. The mixture was incubated in a conventional heat block at 58–65 °C with 1 °C intervals for 60 min, and subsequently at 80 °C for 5 min for the termination. The method on electrophoresis combined with five parts: first step, prepare 1× TBE solutions and poured 2 % agarose gel, second step, add 1/6 volume of 6× loading buffer (1 μl) to amplification products (5 μl) and mixed well, the third step-electrophoresis, voltage 100 V, electrical current 60 mA, time 30 min, the fourth step, remove the gel and visualize bands of DNA under UV (Ultraviolet) light, take pictures. The amplification products were electrophoresed on 2 % agarose gel to confirm the optimal reaction temperature at which the amplification products of all four Vibrio species showed clear ladder banding. The reaction time (15, 30, 45, 60, 75 and 90 min) was optimized, based on the same principle used in the temperature optimization. To prove the primers were species-specific among the target Vibrio species, uni-LAMP assays were carried out under the optimization conditions with the DNA extracted from V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri.

The quadruplex LAMP assay was implemented under the optimal conditions determined above, and the procedure was identical to that of the uni-LAMP, except that four sets of primers (Table 2) were substituted for the one primer set used in the uni-LAMP. To determine the specificity of the quadruplex LAMP method, the quadruplex LAMP was carried out with the DNA template of 31 bacteria strains, whereas the sensitivity of the method was estimated using the DNA from a tenfold serial dilution of each initial adjusted concentration of bacteria (8 × 109 CFU ml−1).

Restriction enzyme-digestion of the amplified DNA products

To identify bacteria species (V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri) corresponding to application products, restriction enzyme-digestion of the products were carried out. Each 5 μl of reaction products were digested with the EcoRI, BamHI, Pst I and EcoRV, respectively, and incubated at 37 °C for 1 h. The quadruplex LAMP products and digested DNA products were subjected to electrophoresis on a 2 % agarose gel and then visualized under an Gel Imaging System (Pei Qing, Shang hai, China).

Polymerase Chain Reaction (PCR)

To determine the limit of the conventional PCR, PCR amplification was carried out with the outer primers (F3s and B3s) for detection of the four Vibrio species. The reaction mixture (25 μl) contained 1 μl DNA template, which estimated using the DNA from a tenfold serial dilution of each initial adjusted concentration of bacteria (8 × 109 CFU ml−1), 2 μl dNTPs (2.5 mM), 0.1 μl Taq DNA Polymerase with its corresponding buffer, and 0.25 μl each of 20 μM primers. The program comprised 94 °C for 5 min; 25 cycles of 94 °C for 30 s, 55 °C for 50 s and 72 °C for 40 s; and 72 °C for 10 min. The PCR products were subjected to electrophoresis and then visualized as described above.

Detection and isolation of Vibrio species from infected fish

V. scophthalmi, V. vulnificus, V. parahaemolyticus and V. ichthyoenteri were cultured in Luria–Bertani (LB) medium (OD600 ≈ 0.8) at 28 °C and collected by centrifugation. The cells were resuspended in PBS. Scophthalmus maximus (averaging 18.4 ± 1.8 g) were purchased from a local fish farm and acclimatized in the laboratory for 2 weeks before experimental manipulation. Fish were fed daily with commercial dry pellets and maintained at 18 °C in tanks supplied with aerated seawater changed daily. Before the experiment, fish were randomly sampled for the examination of bacterial recovery from their blood, liver, kidney, and spleen by the plate-count method, and no bacteria were detected from any of the examined tissues of the sampled fish. Five groups of Scophthalmus maximus were injected by intraperitoneal (i. p.) injection with 5 × 106 CFU V. scophthalmi, V. vulnificus, V. parahaemolyticus, V. ichthyoenteri diluted in 100 μl PBS per fish, respectively, and control fishes were injected i. p. with 100 μl PBS. At 24 h post injection, the fish were euthanized, and tissues such as the blood, kidney, spleen and liver were isolated from the tested fish, homogenized and then boiled with an induction cooker to release the DNA. After the quadruplex LAMP reaction ended with the boiled homogenate of the tissue fluid being used as template, the results were detected visually by adding 1 μl (1:10) SYBR Green I into the mixtures, and the color of the positive amplification products changed from orange to green.

Sensitivity of the quadruplex LAMP in infected fish tissues was determined according to method reported by Yu et al. (2013). Briefly, the LAMP reaction was performed using tenfold serial dilutions of the tissue sample prepared above as LAMP templates. The products were subjected to gel electrophoresis. The bacteria number of the detection limits was determined by the following procedure. The pre-boiled diluted homogenates corresponding to the detection limits were plated in triplicate on LB agar plates. The plates were incubated at 28 °C for 48 h, and the colonies that emerged on the plates were counted. The detection limits were also confirmed by visual inspection with fluorescent staining.

References

  • Akond MA, Alam S, Hasan SMR, Uddin SN, Shirin M (2008) Antibiotic resistance of Vibrio cholerae from poultry sources of Dhaka, Bangladesh. Advan Biol Res 2:60–67

    Google Scholar 

  • Cai SH, Lu YS, Wu ZH, Jian JC, Wang B, Huang YC (2010) Loop-mediated isothermal amplification method for rapid detection of Vibrio alginolyticus, the causative agent of vibriosis in mariculture fish. Lett Appl Microbiol 50(5):480–485

    Article  Google Scholar 

  • Cerdà-Cuéllar M, Blanch AR (2002) Detection and identification of Vibrio scophthalmi in the intestinal microbiota of fish and evaluation of host specificity. J Appl Microbiol 93(2):261–268

    Article  Google Scholar 

  • Chowdhury N, Asakura M, Neogi SB, Hinenoya A, Haldar S, Ramamurthy T, Yamasaki S (2010) Development of simple and rapid PCR-fingerprinting methods for Vibrio cholerae on the basis of genetic diversity of the superintegron. J Appl Microbiol 109(1):304–312

    Google Scholar 

  • Fall J, Chakraborty G, Kono T, Maeda M, Itami T, Sakai M (2008) Establishment of loop-mediated isothermal amplification method (LAMP) for the detection of Vibrio nigripulchritudo in shrimp. FEMS Microbiol Lett 288(2):171–177

    Article  Google Scholar 

  • Haenen OLM, Van Zanten E, Jansen R, Roozenburg I, Engelsma MY, Dijkstra A, Möller AVM (2014) Vibrio vulnificus outbreaks in Dutch eel farms since 1996: strain diversity and impact. Dis Aquat Organ 108(3):201–209

    Article  Google Scholar 

  • Harwood VJ, Gandhi JP, Wright AC (2004) Methods for isolation and confirmation of Vibrio vulnificus from oysters and environmental sources: a review. J Microbiol Methods 59:301–316

    Article  Google Scholar 

  • He L, Xu H (2011) Development of a multiplex loop-mediated isothermal amplification (mLAMP) method for the simultaneous detection of white spot syndrome virus and infectious hypodermal and hematopoietic necrosis virus in penaeid shrimp. Aquaculture 311:94–99

    Article  Google Scholar 

  • Iseki H, Alhassan A, Ohta N, Thekisoe OM, Yokoyama N, Inoue N, Igarashi I (2007) Development of a multiplex loop-mediated isothermal amplification (mLAMP) method for the simultaneous detection of bovine Babesia parasites. J Microbiol Methods 71(3):281–287

    Article  Google Scholar 

  • Ishimaru K, Akagawa-Matsushita M, Muroga K (1996) Vibrio ichthyoenteri sp. nov., a pathogen of Japanese flounder (Paralichthys olivaceus) larvae. J Syst Evol Microbiol 46:155–159

    Google Scholar 

  • Iwamoto T, Sonobe T, Hayashi K (2003) Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M. avium, and M. intracellulare in sputum samples. J Clin Microbiol 41:2616–2622

    Article  Google Scholar 

  • Iwamoto M, Ayers T, Mahon BE, Swerdlow DL (2010) Epidemiology of seafood-associated infections in the United States. Clin Microbiol Rev 23(2):399–411

    Article  Google Scholar 

  • Kubota K, Iwasaki E, Inagaki S, Nokubo T, Sakurai Y, Komatsu M, Morikawa K (2008) The human health burden of foodborne infections caused by Campylobacter, Salmonella, and Vibrio parahaemolyticus in Miyagi Prefecture. Japan. Foodborne Pathog Dis 5(5):641–648

    Article  Google Scholar 

  • Lee DC, Han HJ, Choi SY, Kronvall G, Park CI, Kim DH (2012) Antibiograms and the estimation of epidemiological cut off values for Vibrio ichthyoenteri isolated from larval olive flounder, Paralichthys olivaceus. Aquaculture 342:31–35

    Article  Google Scholar 

  • Mao Z, Qiu Y, Zheng L, Chen J, Yang J (2012) Development of a visual loop-mediated isothermal amplification method for rapid detection of the bacterial pathogen Pseudomonas putida of the large yellow croaker (Pseudosciaena crocea). J Microbiol Methods 89(3):179–184

    Article  Google Scholar 

  • Maria H, Eric WB, Peter CHF, Christine EK, Markus F, Steven RM (2010) PCR-based method for targeting 16S-23S rRNA intergenic spacer regions among Vibrio species. BMC Microbiol 10:90

    Article  Google Scholar 

  • Montilla R, Palomar J, Santmarti M, Fuste C, Viñas M (1994) Isolation and characterization of halophilic Vibrio from bivalves bred in nurseries at the Ebre Delta. J Invertebr Pathol 63(2):178–181

    Article  Google Scholar 

  • Myoung SK, Ji YC, Hye SC (2014) Identification of Vibrio harveyi, Vibrio ichthyoenteri, and Photobacterium damselae isolated from olive flounder Paralichthys olivaceus in Korea by multiplex PCR developed using the rpoB gene. Fish Sci 80:333–339

    Article  Google Scholar 

  • Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, Hase T (2000) Loop-mediated isothermal amplification of DNA. Nucleic Acids Res 28(12):e63

    Article  Google Scholar 

  • Qiao G, Lee DC, Woo SH, Li H, Xu DH, Park SI (2012) Microbiological characteristics of Vibrio scophthalmi isolates from diseased olive flounder Paralichthys olivaceus. Fisheries Sci 78(4):853–863

    Article  Google Scholar 

  • Quintoil N, Porteen K, Pramanik AK (2007) Studies on occurrence of Vibrio parahaemolyticus in fin fishes and shellfishes from different ecosystem of West Bengal. Livest Res Rural Dev (serial online) 19(1). http://www.lrrd.org/lrrd19/1/quin19001.htm

  • Sawabe T, Yoshizawa A, Kawanishi Y, Komatsu-Takeda E, Nakagawa S, Sawabe T, Yamazaki K (2009) Multi-probe-fluorescence in situ hybridization for the rapid enumeration of viable Vibrio parahaemolyticus. Microbes Environ 24(3):259–264

    Article  Google Scholar 

  • Strom MS, Paranjpye RN (2000) Epidemiology and pathogenesis of Vibrio vulnificus. Microbes Infect 2(2):177–188

    Article  Google Scholar 

  • Toranzo AE, Magariños B, Romalde JL (2005) A review of the main bacterial fish diseases in mariculture systems. Aquaculture 246(1):37–61

    Article  Google Scholar 

  • Yamazaki W, Ishibashi M, Kawahara R, Inoue K (2008) Development of a loop-mediated isothermal amplification assay for sensitive and rapid detection of Vibrio parahaemolyticus. BMC Microbiol 8(1):1

    Article  Google Scholar 

  • Yu L, Hu Y, Zhang X, Sun BG (2013) Development of a triplex loop-mediated isothermal amplification method for rapid on-site detection of three Vibrio species associated with fish diseases. Aquaculture 414:267–273

    Article  Google Scholar 

Download references

Authors’ contributions

SZ, ZG and MZ contributed collaboratively to all aspects of this work; DL, participated in Optimization of the LAMP reaction conditions; XZ, participated in Specificities of the quadruplex LAMP method; YL, participated in applicability of the quadruplex LAMP method. All authors read and approved the final manuscript.

Acknowledgements

This study were financially supported by the Technology Development Project of Shandong Province (6682214005), the Fishery Industry Innovation Team, Modern Agricultural Industry and Technology System of Shandong Province (SDAIT-12-06), the International Cooperation Training project of Excellent Backbone Teacher of Shandong Provincial Department of Education, and the project for Advanced Talents Foundation of Qingdao Agricultural University (6631114322).

Competing interests

The authors declare that they have no competing interests.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shun Zhou.

Additional information

Shun Zhou, Zhi-xin Gao and Min Zhang contributed equally to this work

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhou, S., Gao, Zx., Zhang, M. et al. Development of a quadruplex loop-mediated isothermal amplification assay for field detection of four Vibrio species associated with fish disease. SpringerPlus 5, 1104 (2016). https://doi.org/10.1186/s40064-016-2760-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40064-016-2760-x

Keywords